Scotopic sensitivity and color vision with a blue-light-absorbing intraocular lens.

Greenstein VC, Chiosi F, Baker P, Seiple W, Holopigian K, Braunstein RE, Sparrow JR

Department of Ophthalmology, Columbia University, New York, NY 10032, USA. vcg1@nyu.edu

PURPOSE: To investigate possible adverse effects of a yellow-tinted intraocular lens (IOL) on scotopic sensitivity and hue discrimination. SETTING: Departments of Ophthalmology, Columbia University and New York University School of Medicine, New York, New York, USA. METHODS: Nine patients with a yellow-tinted IOL in 1 eye and a colorless ultraviolet IOL in the fellow eye and 9 young phakic subjects with and without a yellow-tinted clip-on lens were tested. Hue discrimination was measured with the Farnsworth-Munsell (FM) 100-hue test. Dark-adapted thresholds to 440 nm, 500 nm, and 650 nm lights were measured at 23 locations using a modified Humphrey perimeter, and dark-adapted thresholds to white light were measured at 15 degrees temporal retina. RESULTS: In the 9 patients, there were no significant differences in dark-adapted sensitivities to 440, 500, 650 nm, or white-light stimuli and no differences in FM 100-hue error scores between eyes with yellow-tinted IOLs and those with colorless IOLs. Similarly, in young phakic subjects, there were no significant differences in FM 100-hue error scores or dark-adapted sensitivity to the white light with and without the yellow-tinted clip-on lens. However, with the clip-on lens, mean sensitivities to the 440 nm, 500 nm, and 650 nm stimuli were significantly decreased by 2.7 to 2.8 dB, 0.7 to 1.0 dB, and 0 to 1.2 dB, respectively. CONCLUSION: Results suggest that implantation of a yellow-tinted IOL has non-significant effect on scotopic sensitivity and hue discrimination.

Published 2 April 2007 in J Cataract Refract Surg, 33(4): 667-72.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Ophthalmology Research Today. All Rights Reserved.



Ophthalmology Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)



Ophthalmology Books

Current Diagnosis and Treatment in Otolaryngology (Current Diagnosis & Treatment)

Current Diagnosis and Treatment in Otolaryngology (Current Diagnosis & Treatment)