Ophthalmology Research - Eye Surgery, Myopia, Cataracts

Ophthalmology Research Today is a free monthly online journal that collates and summarizes the latest research about Ophthalmology, including details on eye surgery, myopia, cataracts.


Ophthalmology Research Today

Home

View Latest Issue

Information About Ophthalmology

Books on Ophthalmology

Advertising in Research Today

View Other Research Today Publications



Assessment and reproducibility of anterior chamber depth measurement with anterior segment optical coherence tomography compared with immersion ultrasonography.

Nemeth G, Vajas A, Tsorbatzoglou A, Kolozsvari B, Modis L, Berta A

Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary. nemeth222@yahoo.com

PURPOSE: To measure anterior chamber depth (ACD) with an anterior segment optical coherence tomography (AS-OCT) and a standard ultrasonic (US) axial scan (A-scan) device using an immersion technique and to assess repeatability, reproducibility, and correlations of the measurements. SETTING: Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary. METHODS: Sixty healthy eyes of 41 patients were enrolled in a study. The central ACD was measured 5 times with AS-OCT (Visante, Carl Zeiss Meditec) using its chamber tool and 5 times with a US A-scan device (UltraScan Imaging System, Alcon Laboratories) using an immersion method. The measurements were performed consecutively by 2 independent observers. RESULTS: The mean ACD measured with AS-OCT was 3.12 mm +/- 0.33 (SD) by observer 1 and 3.11 +/- 0.33 mm by observer 2 (P = .78). The repeatability was 0.8% +/- 0.4% and 1.9% +/- 1.4%, respectively. The reproducibility was 0.23%. The reliability coefficient with AS-OCT was 99.6%. The mean ACD measured with immersion US A-scan was 2.98 +/- 0.33 mm by observer 1 and 2.95 +/- 0.34 mm by observer 2 (P = .68) . The repeatability was 6.4% +/- 3.8% by observer 1 and 8.5% +/- 4.9% by observer 2. The reproducibility was 0.88%. The reliability coefficient was 87.1% for US A-scan measurements. The difference between ACD values with AS-OCT and values with US A-scan was statistically significant (P = .02). The correlation (r) between AS-OCT and US A-scan was 0.732 (P<.0001) by observer 1 and 0.802 (P<.0001) by observer 2. CONCLUSIONS: Anterior chamber measurements were significantly deeper with AS-OCT than with US immersion A-scan. Repeatability of ACD measurements was better with AS-OCT than with immersion US, and reproducibility was equal with the 2 methods.

Published 26 February 2007 in J Cataract Refract Surg, 33(3): 443-7.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Ophthalmology Research Today. All Rights Reserved.



Ophthalmology Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)



Ophthalmology Books

Cornea (2-Volume Set with DVD)

Cornea (2-Volume Set with DVD)