Ophthalmology Research - Eye Surgery, Myopia, Cataracts

Ophthalmology Research Today is a free monthly online journal that collates and summarizes the latest research about Ophthalmology, including details on eye surgery, myopia, cataracts.


Ophthalmology Research Today

Home

View Latest Issue

Information About Ophthalmology

Books on Ophthalmology

Advertising in Research Today

View Other Research Today Publications



Influence of 360-degree enhanced optic edge design of a hydrophilic acrylic intraocular lens on posterior capsule opacification.

Nishi Y, Rabsilber TM, Limberger IJ, Reuland AJ, Auffarth GU

International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany.

PURPOSE: To compare the rate of posterior capsule opacification (PCO) with the single-piece hydrophilic acrylic foldable Rayner Centerflex 570H intraocular lens (IOL), which has a sharp optic edge design excluding the optic-haptic junction, and the Rayner C-flex 570C IOL, which has an improved 360-degree sharp edge. SETTING: Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. METHODS: As part of a multicenter U.S. Food and Drug Administration (FDA) study, 42 patients who had implantation of a C-flex IOL in 1 eye after uneventful phacoemulsification were enrolled. Six and 12 months postoperatively, PCO was evaluated by retroillumination photographs using Evaluation of Posterior Capsule Opacification (EPCO) 2000 image-analysis software. The data were then compared with those in a matched group of patients with a Centerflex IOL who participated in a previous FDA study. RESULTS: The mean age of the patients with the C-flex IOL was 71.5 years +/- 8.2 (SD) There was a statistically significant difference in EPCO scores between the C-flex group and Centerflex group. Six months after surgery, the mean EPCO value (total IOL optic) was 0.07 +/- 0.17 in the C-flex group (n = 37) and 0.20 +/- 0.20 in the Centerflex group (n = 36) (P<.01, Wilcoxon test). By 12 months, the mean had increased to 0.16 +/- 0.20 in the C-flex group (n = 37) and 0.35 +/- 0.22 in the Centerflex group (n = 31) (P<.01, Wilcoxon test). CONCLUSIONS: The C-flex IOLs showed good functional results and significantly lower PCO formation than the earlier model Centerflex IOL. The enhanced edge of the C-flex IOL seemed to improve PCO prevention clinically.

Published 5 February 2007 in J Cataract Refract Surg, 33(2): 227-31.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Ophthalmology Research Today. All Rights Reserved.



Ophthalmology Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Ophthalmology Books

Ophthalmology Pearls

Ophthalmology Pearls