Goldmann tonometer calibration: a national survey.

Kumar N, Hillier RJ

1Ophthalmology Department, Aintree University Hospitals NHS Foundation Trust, Walton Hospital, Rice Lane, Liverpool, UK.

IntroductionRecent studies suggest that Goldmann tonometers can rapidly develop calibration errors (CEs) in clinical use and routine checks are necessary to ensure accuracy.PurposeTo determine current practice regarding CE checks in the United Kingdom and assess the views of senior nursing staff in charge of running ophthalmology outpatient clinics as to whom they feel to be responsible for CE checks.MethodsEvery ophthalmology unit with training recognition in England, Northern Ireland, Scotland, and Wales was contacted. Senior nurses responded to a structured telephone questionnaire regarding local tonometer calibration practice and their views regarding who is responsible for CE checks. A total of 155 eye units were identified and contacted. The response rate was 100%.ResultsCEs were checked for daily in 8 units (5.2%), weekly in 20 units (12.9%), fortnightly in 1 unit (0.6%), monthly in 12 units (7.7%), trimonthly in 5 units (3.2%), biannually in 27 units (17.4%), and annually in 21 units (13.5%). CEs were either never checked or checked in a very random manner (no identifiable pattern) in 61 units (39.4%). Sixty-three (40.6%) of the respondents felt CE checks were a departmental responsibility, 48 (31.0%) felt it to be the doctor's responsibility, and 44 (28.4%) felt CE checks should be performed by the nursing staff.ConclusionsOur national survey suggests that very few units check their tonometers for CEs at intervals which ensure their accuracy. Our previous survey of doctors suggests that they believe nurses should check for CE, whereas the nursing staff believe CE checks are not their responsibility. This lack of communication between health-care professionals may lead to inaccurate tonometers being used in clinical practice. We suggest that every eye unit should have a protocol, which clearly identifies individuals responsible for checking for CEs at least on a monthly basis.Eye advance online publication, 26 October 2007; doi:10.1038/sj.eye.6703010.

Published 26 October 2007 in Eye.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Ophthalmology Research Today. All Rights Reserved.



Ophthalmology Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Ophthalmology Books

Oxford Handbook of Ophthalmology (Oxford Handbook Series)

Oxford Handbook of Ophthalmology (Oxford Handbook Series)