Ophthalmology Research - Eye Surgery, Myopia, Cataracts

Ophthalmology Research Today is a free monthly online journal that collates and summarizes the latest research about Ophthalmology, including details on eye surgery, myopia, cataracts.


Ophthalmology Research Today

Home

View Latest Issue

Information About Ophthalmology

Books on Ophthalmology

Advertising in Research Today

View Other Research Today Publications



Effect of anterior capsule polishing on the posterior capsule opacification-inhibiting properties of a sharp-edged, 3-piece, silicone intraocular lens: three- and 5-year results of a randomized trial.

Bolz M, Menapace R, Findl O, Sacu S, Buehl W, Wirtitsch M, Leydolt C, Kriechbaum K

Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.

PURPOSE: To evaluate the long-term effects of anterior capsule polishing on regeneratory posterior capsule opacification (PCO), anterior capsule opacification (ACO), and fibrotic PCO with a silicone intraocular lens (IOL) with sharp optic edges. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: This prospective bilateral randomized patient- and examiner-masked clinical trial comprised 130 eyes of 65 patients with bilateral age-related cataract. All eyes had implantation of a 3-piece silicone IOL with a truncated, sharp-edged optic (CeeOn Edge 911A, Advanced Medical Optics). In 1 eye, the anterior capsule was extensively polished using an aspiration curette after phacoemulsification and cortex aspiration. Regenerative PCO was quantified objectively, while ACO and fibrotic PCO were graded subjectively 1, 2, 3, and 5 years postoperatively. RESULTS: The mean ACO score was significantly lower in the eyes in which the anterior capsule had been polished (1 year, P<.02; 2 years, P<.03; 3 years, P<.01; 5 years, P<.01). The mean difference in regeneratory PCO and fibrotic PCO scores between the 2 groups was not statistically significant. CONCLUSIONS: Three years after cataract surgery, eyes in which the anterior capsule had been polished had significantly less ACO. However, polishing did not lower PCO intensity when a sharp-edged CeeOn 911A IOL was implanted in the bag. Although results indicate that anterior capsule polishing may enhance the development of regeneratory PCO, this trend did not reach statistical significance.

Published 25 August 2006 in J Cataract Refract Surg, 32(9): 1513-20.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Ophthalmology Research Today. All Rights Reserved.



Ophthalmology Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)



Ophthalmology Books

Cosmetic and Clinical Applications of Botox and Dermal Fillers

Cosmetic and Clinical Applications of Botox and Dermal Fillers