Ophthalmology Research - Eye Surgery, Myopia, Cataracts

Ophthalmology Research Today is a free monthly online journal that collates and summarizes the latest research about Ophthalmology, including details on eye surgery, myopia, cataracts.


Ophthalmology Research Today

Home

View Latest Issue

Information About Ophthalmology

Books on Ophthalmology

Advertising in Research Today

View Other Research Today Publications



Quantitative thermographic analysis of viscoelastic substances in an experimental study in rabbits.

Jurowski P, Goś R, Kuśmierczyk J, Owczarek G, Gralewicz G

Department of Ophthalmology and Visual Rehabilitation, Medical University of Lodz, Poland. p.jurowski@poczta.wprost.pl

PURPOSE: To measure the temperature parameters on the corneal surface during the delivery of standardized ultrasound energy assisted with ophthalmic viscosurgical devices (OVDs) or different temperatures of irrigating solutions in an experimental animal model. SETTING: Department of Ophthalmology and Visual Rehabilitation, Medical University of Lodz, and Central Institute for Labor Protection, National Research Institute, Warsaw, Poland. METHODS: Thirty rabbits (60 eyes) were randomly divided into 6 groups in which different OVD or balanced salt solutions (BSS) were used: group 1: Viscoat (sodium hyaluronate 3%-chondroitin sulfate); group 2: Provisc (sodium hyaluronate 1%); group 3: soft-shell technique; group 4: Celoftal (hydroxypropyl methylcellulose 2%); group 5: BSS 22 degrees C; and group 6: BSS 4 degrees C. After the nucleus and lens cortex were removed, the anterior chamber was filled with OVD or BSS and a phaco tip was introduced into the pupillary plane and switched on. The same phaco tip parameters were used in all groups. For thermographic measurements (ie, maximal temperature [MT], dynamic rise in temperature [DRT], and time when the maximal level of temperature [TMLT] was achieved), a thermocamera was used. RESULTS: Mean preoperative temperature on the rabbit corneal surface was 22.76 degrees C +/- 1.48 degrees C (SD). Working with a phaco tip increased the temperature in each group. A significantly higher MT was observed in group 5 (27.85 degrees C +/- 0.52 degrees C), followed by group 2 (27.75 degrees C +/- 0.54 degrees C), group 3 (27.74 degrees C +/- 0.46 degrees C), and group 4 (27.25 degrees C +/- 0.60 degrees C), than in group 6 (26.81 degrees C +/- 0.34 degrees C) and group 1 (26.52 degrees C +/- 0.48 degrees C) (P<.05). Significantly higher values of DRT and shorter TMLT values were observed in group 5 (1.16 degrees C/s +/- 0.42 degrees C/s, 4 seconds) and group 6 (0.91 degrees C/s +/- 0.13 degrees C/s, 5 seconds) than in groups 2, 3, 1, and 4 (0.09 degrees C/s +/- 0.07 degrees C/s, 30 seconds; 0.08 degrees C/s +/- 0.04 degrees C/s, 40 seconds; 0.07 degrees C/s +/- 0.03 degrees C/s, 45 seconds; 0.06 degrees C/s +/- 0.02 degrees C/s, 50 seconds, respectively) (P<.0001). CONCLUSIONS: Currently used OVDs potentially offer different levels of protection against the increase in temperature that occurs during phacoemulsification. Therefore, the surgeon should consider this aspect when choosing an OVD, particularly in difficult cases (ie, hard nucleus, shallow anterior chamber, endothelial abnormalities).

Published 6 March 2006 in J Cataract Refract Surg, 32(1): 137-40.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Ophthalmology Research Today. All Rights Reserved.



Ophthalmology Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)



Ophthalmology Books

Cornea (2-Volume Set with DVD)

Cornea (2-Volume Set with DVD)