Ophthalmology Research - Eye Surgery, Myopia, Cataracts

Ophthalmology Research Today is a free monthly online journal that collates and summarizes the latest research about Ophthalmology, including details on eye surgery, myopia, cataracts.


Ophthalmology Research Today

Home

View Latest Issue

Information About Ophthalmology

Books on Ophthalmology

Advertising in Research Today

View Other Research Today Publications



Burst-shot infrared digital photography to determine scotopic pupil diameter.

Yang H, Lee M, Kim JB, Ahn J

From the Department of Ophthalmology, Ajou University School of Medicine, Suwon, Korea.

PURPOSE: To evaluate the usefulness of infrared digital photography for determining scotopic pupil size by comparing infrared digital photography with a Colvard pupillometer (Oasis Medical). SETTING: Department of Ophthalmology, Ajou University School of Medicine, Suwon, Korea. METHODS: Scotopic pupil size in 50 eyes of 25 healthy individuals was measured with a Colvard pupillometer and a digital camera (DSC-F828) using infrared burst shots after 5 minutes of dark adaptation. Measurements were performed by 2 independent examiners (E1 and E2). The digital photograph images were read using the ruler function of Adobe Photoshop 7.0 by 2 independent readers (R1 and R2). Agreement and repeatability were analyzed using the comparison method described by Bland and Altman. RESULTS: The mean scotopic pupil diameter measured using the Colvard pupillometer was 6.69 mm +/- 0.78 (SD) (E1) and 6.70 +/- 0.71 mm (E2). The mean scotopic pupil diameter measured from the digital photograph images was 6.67 +/- 0.75 mm (E1) and 6.66 +/- 0.78 mm (E2). The mean difference between E1 and E2 with both devices was small; however, the result with the infrared digital camera was marginally smaller than with the Colvard pupillometer. The limits of agreement were -0.01 +/- 0.70 mm with the Colvard pupillometer and 0.01 +/- 0.20 mm with the digital photograph image. The digital photograph image showed better agreement. The coefficient of interrater repeatability was smaller for the digital photograph image (0.39) than for the Colvard pupillometer (0.70). CONCLUSIONS: Scotopic pupil measurement using an infrared digital camera with a burst shot had good agreement with the Colvard pupillometer and better repeatability. The infrared digital camera is less expensive, and pupil unrest can be overcome by taking serial images.

Published 1 December 2006 in J Cataract Refract Surg, 32(12): 2113-7.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Ophthalmology Research Today. All Rights Reserved.



Ophthalmology Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Ophthalmology Books

Cosmetic and Clinical Applications of Botox and Dermal Fillers

Cosmetic and Clinical Applications of Botox and Dermal Fillers