Internal anterior chamber diameter using optical coherence tomography compared with white-to-white distances using automated measurements.

Kohnen T, Thomala MC, Cichocki M, Strenger A

Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. kohnen@em.uni-frankfurt.de

PURPOSE: To compare internal horizontal anterior chamber (AC) diameter determined by optical coherence tomography (OCT) and horizontal corneal diameter (white-to-white [WTW]) using automated measurements. SETTING: Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS: Internal AC diameter and WTW distance was measured in 52 eyes of 26 patients using the Visante OCT (Carl Zeiss Meditec), IOLMaster (Carl Zeiss Meditec), and Orbscan IIz topography system (Bausch & Lomb). Statistical evaluation was performed using the Bland-Altman method and regression analysis for comparison of measurement techniques. The Kruskal-Wallis test was used to measure the repeatability of each device. RESULTS: The mean internal AC diameter was 12.45 mm +/- 0.53 (SD) with OCT; the mean WTW distance was 12.17 +/- 0.45 mm with the IOLMaster and 11.84 +/- 0.41 mm with the Orbscan IIz. A positive regression was determined for AC diameter and both WTW measurements. Measurement values varied little between both WTW measurement systems (R(2) = 0.9384). CONCLUSIONS: Anterior chamber measurement using optical coherence tomography (Visante OCT) was easy to handle and showed good repeatability. The internal horizontal diameter of the AC was larger than the horizontal corneal diameter determined by automated WTW measurements (IOLMaster, Orbscan IIz). Optical coherence tomography with the Visante OCT allows direct measurement of the AC width.

Published 3 November 2006 in J Cataract Refract Surg, 32(11): 1809-13.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Ophthalmology Research Today. All Rights Reserved.



Ophthalmology Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Ophthalmology Books

Oxford Handbook of Ophthalmology (Oxford Handbook Series)

Oxford Handbook of Ophthalmology (Oxford Handbook Series)