Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.

Kurz S, Krummenauer F, Dumbach C, Pfeiffer N, Dick HB

Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. kurz@augen.klinik.uni-mainz.de

PURPOSE: To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage. SETTING: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. METHODS: In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulorhexis diameter were measured intraoperatively and 2 or 3 days as well as 1 and 3 months postoperatively. RESULTS: There were no statistically significant or clinically relevant between-group differences in covariants such as axial length, vertical and horizontal corneal radii, and capsulorhexis diameter. Eyes with the CTR had slight but statistically significant capsular bag shrinkage from a median of 10.4 to a median of 10.2 mm after 3 months (P<.001). Eyes with the CFER also had slight but statistically significant capsular bag shrinkage from a median of 10.3 to a median of 10.2 mm 3 months postoperatively (P = .021). At baseline, the CTR group had a larger capsular bag diameter, but there were no statistically significant differences between the groups at the 3-month follow-up (P = .669). CONCLUSIONS: No clinically relevant capsular bag shrinkage was observed after implantation of a CFER or a CTR. The expected capsular bag shrinkage was the same in both groups.

Published 2 October 2006 in J Cataract Refract Surg, 32(10): 1615-20.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Ophthalmology Research Today. All Rights Reserved.



Ophthalmology Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Ophthalmology Books

Retina: Color Atlas and Synopsis of Clinical Ophthalmology (Wills Eye Series)

Retina: Color Atlas and Synopsis of Clinical Ophthalmology (Wills Eye Series)