Ophthalmology Research - Eye Surgery, Myopia, Cataracts

Ophthalmology Research Today is a free monthly online journal that collates and summarizes the latest research about Ophthalmology, including details on eye surgery, myopia, cataracts.


Ophthalmology Research Today

Home

View Latest Issue

Information About Ophthalmology

Books on Ophthalmology

Advertising in Research Today

View Other Research Today Publications



Pediatric Amblyopia Risk Investigation Study (PARIS).

Savage HI, Lee HH, Zaetta D, Olszowy R, Hamburger E, Weissman M, Frick K

Department of Ophthalmology, George Washington University, 2100 Pennsylvania Avenue NW, 4th Floor, Washington, DC 20037, USA. Howard.savage@gmail.com

PURPOSE: To assess the learning curve, testability, and reliability of vision screening modalities administered by pediatric health extenders. DESIGN: Prospective masked clinical trial. METHODS: Two hundred subjects aged 3 to 6 underwent timed screening for amblyopia by physician extenders, including LEA visual acuity (LEA), stereopsis (RDE), and noncycloplegic autorefraction (NCAR). Patients returned for a comprehensive diagnostic eye examination performed by an ophthalmologist or optometrist. RESULTS: Average screening time was 5.4 +/- 1.6 minutes (LEA), 1.9 +/- 0.9 minutes (RDE), and 1.7 +/- 1.0 minutes (NCAR). Test time for NCAR and RDE fell by 40% during the study period. Overall testability was 92% (LEA), 96% (RDE), and 94% (NCAR). Testability among 3-year-olds was 73% (LEA), 96% (RDE), and 89% (NCAR). Reliability of LEA was moderate (r = .59). Reliability of NCAR was high for astigmatism (Cyl) (r = .89), moderate for spherical equivalent (SE) (r = .66), and low for anisometropia (ANISO) (r = .38). Correlation of cycloplegic autorefraction (CAR) with gold standard cycloplegic retinoscopic refraction (CRR) was very high for SE (.85), CYL (.77), and moderate for ANISO (.48). CONCLUSIONS: With NCAR, physician extenders can quickly and reliably detect astigmatism and spherical refractive error in one-third the time it takes to obtain visual acuity. LEA has a lower initial cost, but is time consuming, moderately reliable, and more difficult for 3-year-olds. Shorter examination time and higher reliability may make NCAR a more efficient screening tool for refractive amblyopia in younger children. Future study is needed to determine the sensitivity and specificity of NCAR and other screening methods in detecting amblyopia and amblyopia risk factors.

Published 26 December 2005 in Am J Ophthalmol, 140(6): 1007-13.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Ophthalmology Research Today. All Rights Reserved.



Ophthalmology Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Ophthalmology Books

Surgical Techniques in Ophthalmology Series: Glaucoma Surgery: Text with DVD (Surgical Techniques in Ophthalmology)

Surgical Techniques in Ophthalmology Series: Glaucoma Surgery: Text with DVD (Surgical Techniques in Ophthalmology)